data acquisition card (daq) module model usb-6343 (National Instruments Inc)
Structured Review

Data Acquisition Card (Daq) Module Model Usb 6343, supplied by National Instruments Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/data+acquisition+card+%28daq%29module+model+usb-6343/pmc08714743-75-13-21?v=National+Instruments+Inc
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System"
Article Title: Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
Journal: Frontiers in Bioengineering and Biotechnology
doi: 10.3389/fbioe.2021.799312
Figure Legend Snippet: Design of integrated electric signal recording and electric pulse regulating system. (A) The system structure of integrated electric signal recording and electric pulse regulating system: biosensor units, hardware module, and software module. The hardware module includes a signal processing module (blue), electroporation module (orange), and a DAQ module (green). The functions of the software module include waveform display, data storage and pulse control (pink). (Numbers in parentheses indicate the corresponding labelled components in (B,C) ) (B) Signal processing module (integrated 32-channel signal processing circuit) diagram. (C) Electroporation module (integrated 32-channel electroporation circuit) diagram. (D) The software user interface of integrated electrical signal recording and electrical pulse regulating system. (E) The internal wiring of the shielding box. The ground wire of the shielding box is connected to the ground of the power supply, which can effectively shield the interference of power frequency noise and high frequency noise. (F) The photo of the integrated electrical signal recording and electrical pulse regulating system.
Techniques Used: Software, Electroporation, Control
Figure Legend Snippet: Performance test of the electrical signal recording and electrical pulse regulating system. (A) Bode plot of the signal processing circuit. (B) Deviation of the pulse amplitude generated by DAQ. (C) Deviation of the pulse frequency generated by DAQ. In actual experiments, the frequency range of the electroporation pulses is 10–100 Hz, so the commonly used frequency points are selected for testing. (D) Deviation of pulse width generated by DAQ. (E) SNR comparison between shield box and no shield box. (F) Sensor performance test of NPMEA with PBS (Curves in different colors represented all 32 channels of a sensor).
Techniques Used: Generated, Electroporation, Comparison